Square
1800 m²
Year
2020
General information:
Total area:
1800 m²
Cold consumers:
An ice field pipe system in which low temperature coolant circulates (40% ethylene glycol solution)
Applicable refrigerant of a refrigeration supply system:
Freon R404A.
Refrigeration supply system type:
Intermediate refrigerant system based on 40% ethylene glycol solution. The coolant temperature up to -15 ° С.
Total refrigerating capacity:
536 Kw.
Heat recovery system:
30 kW to protect the base of the ice field from freezing.
Type of condensers of a refrigeration system:
Air-cooling condensers.
Executed work:
Refrigeration supply system:
Development and production of a refrigerating machine ( chiller with a heat recovery system) for cooling the ice field. Supply of air-cooling condensers with a capacity of more than 700 kW.